Adjusts the fusing idling time:
[0~900/1 s]
Increase this value when fusing on the 1st and 2nd copies is not completed due to low room
temperature.
1104 [Fusing Temperatu] Fusing Temperature Control
Selects the fusing temperature control mode.
[0~1/1]
0: On/Off control
1: Phase control
If power supply to the machine is unstable, select Phase Control. The machine must be switched
off and on after this setting is changed for the new setting to take effect.
Phase control could interfere with radio or TV reception.
1105 [Fusing Tem Adju] Fusing Temperature Adjustment
Adjusts the fusing temperature of the hot roller for plain paper, OHP or thick paper.
001
Normal Time (Center Thermis-
tor)
Fusing temperature during the ready condition and during
printing.
[150~230/1 degree C]
002 Normal Time (End Thermistors)
Fusing temperature during the ready condition
[180~205/1 degree C]
003 OHP (Center Thermistor)
Fusing temperature during printing:
[150~230/1 degree C]
004 OHP (End Thermistor)
Fusing temperature during printing:
[180~205/1 degree C]
005 Thick Paper (Center Thermistor)
Fusing temperature during printing:
[180~205/1 degree C]
006 Thick Paper (End Thermistors)
Fusing temperature during printing:
[180~205/1 degree C]
1106 [Fusing Temp Disp] Fusing Temperature Display
5. Service Tables