106
65.1 ESC+BC CODE93 Barcode
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specifying CODE93 barcode.
[Format]
<BC>aabbbccn~n
●Parameter
a[Narrow bar width] = Valid range : 01 to 36 dots
b[Height of barcode] = Valid range : 001 to 999 dots
c[Digit No. of data] = Valid range : 01 to 99
n[Print data] = Barcode data (Refer to the CODE93 - Code Table)
[Coding Example] Narrow bar width : 02 Height of barcode : 120 Digit No : 12 Print data : ABCD123456xy
<A>
<V>100<H>200<BC>0212012ABCD123456xy
<Q>2
<Z>
[Notes]
1. C/D is an auto-generation.
2. Start code and stop code is automatically added.
3. Maximum entry digit number of data is 99.
4. [Digit No. of data] and No. of input data has to be equal.
5. Command error will occur when No. of input data and [Digit No. of data] is not matching.
CODE93 Barcode