129
75.1 ESC+2D12 Micro PDF417
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify Micro PDF417.
[Format](setting part)
<2D12>,aa,bb,c,dd(,e)
●Parameter
a[Minimum module width] = Valid range : 01~27 (dots)
b[Minimum module height] = Valid range : 01~72 (dots)
c[Data codeword number per 1 line](Cols) = Valid range : 1~4
d[Lines per a symbol](Rows) = Valid range : 2 digits
e[Binary mode specification] = 0 : Normal, 0 when omitted (Omissible)
1 : Binary mode
[Format](data part)
<DN>mmmm,n~n : When Binary mode specification is "Binary mode"
<DS>n~n : When Binary mode specification is "Normal"
●Parameter
m[Number of data] = Valid range : 0001~0366(bytes)
n[Print data] = data
[Coding Example] Module width: 02(dots), minimum module height: 04(dots)
data codeword number per 1 line: 1, lines per a symbol: 14
<A>
<V>100<H>200<2D12>,02,04,1,14
<DN>0010,0123456789
<Q>2
<Z>
[Notes]
1. Lines per a symbol is decided according to the data codeword number per 1 line.
Refer to the "Symbol size and number of data for Micro PDF417" in the next page.
2. Recommend to specify more than 2 dots for 8dots/mm, 12dots/mm, and more than 4 dots for 24dots/mm because the code
with the minimum module width and the minimum module height may not be read by a scanner.
3. The generation module has been changed for the quality improvement. The generated image may be different, however, the
reading result is the same.
Micro PDF417