14
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The set parameter is in effect until a new specification is made.
The parameter preset will be invalid.
[Function]
Specifying a job name for status return.
[Format]
<WK>aaaaaaaaaaaaaaaa
●Parameter
a[Job Name] = ASCII code 16-digit, Shift JIS Kanji 8-digit
[Coding Example] Job name: SATO
<A>
<ID>01
<WK>SATO
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Notes]
1. When Status4 is used for communication protocol, specified job name can be set to the telegraphic status.
2. Status can be confirmed sending status request (ENQ).
3. Include this command within an item and use when printed by Start of Data Transmission <A> ~ End of Data Transmission
<Z>.
4. This command can be used in combination with Job ID Number <ID>.
[Remarks]
1. In status return communication protocol, this command becomes valid when a status request (ENQ) is received while printing
(Including when QTY≠0, Offline and Error).
2. In status return communication protocol, if status request (ENQ) is received when printing is not in progress (QTY=0, No
received data when power is ON), space (20H) will be set to status and returned.
3. When this command is used more than twice within the item of <A> and <Z>, the last specified value becomes valid.
4. For more information, refer to the “Interface Specifications”.
5. If assigning over 17 characters to a job name, the excess characters are ignored.
Job Name