75
49.1 ESC+T2 Registration of 24×24 dots
External Character
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Registering W24 x H24 dots external character.
[Format]
<T2>abbn~n
●Parameter
a[Selection of registered data type] = H : Registration data in hexadecimal character
B : Registration data in binary code
b[Registered font code address] = H : Within the range from 21 to 7F, up to 95 addresses can be registered.
B : Within the range from 21H to 7FH, up 95 addresses can be registered.
n[External character registration data] = Data
[Coding Example] Registration and printing by binary code of GB18030
<A>
<CC>0
<T2>B<00>16
<00FF ・・・・・・・・・・FF00>16
<Z>
<A>
<CC>0
<V>100<H>200<K2>B<80>16<21>16
<Q>2
<Z>
Registration of 24×24 dots
External Character