234
ESC+&S Registration of Form Overlay
Valid range and
term of
command
When the power switch is OFF
The registered data becomes valid.
The registered data are in effect until a new specification is
made.
The registered data are in effect until a new specification is
made.
[Function]
Specifying the registration of fixed print contents to a memory card.
[Format]
<&S>,aa(,bbbb,ccccc)
●Parameter
a[Registration No.] = Valid range : 1 to 99
b[Size specification of window width] = Valid range : Refer to the table below (Omissible)
c[Size specification of window height] = Valid range : Refer to the table below (Omissible)
[Coding Example]
<A>
<V>100<H>100<XM>,MODEL
<CC>1
<&S>,1
<Z>
[Notes]
1. Specify slot No. with Card Slot for Use <CC> prior to this command.
2. Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with the format to be registered.
3. Registration of identical registration No. is invalid.
4. Both Print data of Graphic <G> and Print of BMP File <GM> can be registered.
5. This command allows up to 99 registries. Note that the capacity of registry may vary depending on the memory card to
be used.
6. Data registered with this command can be cleared with Clear <*>R.
7. The error occurs when unused or the slot which the printer is allocated is specified (Refer to Card Slot for Use <CC>).
[Important]
Do not turn the printer power off when accessing to the memory. When the printer power is off while memory accessing,
the data in the accessed media may be corrupted.
[Valid range of the window size]
[S84-ex]
Horizontal direction available
range(dot)
Vertical direction available
range(dot)
[S86-ex]
Horizontal direction available
range(dot)
Vertical direction available
range(dot)
Registration of Form Overlay