16.3 RFID Command
84.1 ESC+F EPC Sequential number
ESC+F
Hexadecimal
code
ESC
F
Parameter
<1B>16
<46>16
aaaabcccc(,dd,ee,f)
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The parameter preset will be invalid.
Valid range between item
The parameter preset will be invalid.
[Function]
This command is set before EPC code write (<IP0> command), and is used to write the sequential number of the
specified data to the EPC area.
[Format]
<F>aaaabcccc(,dd,ee,f)
●Parameter
aaaa "Number of printing for the same contents" = Valid range : 1 to 9999
b "Increment/decrement setting" = : Addition
: Subtraction
cccc "Increment/decrement value setting" = Valid range : to 9999
dd "Sequential numbering digits" = Valid range : 1 to 24, 24 if omitted (omissible)
ee "Lower disabled digits" = Valid range : 0 to 99, 0 if omitted (omissible)
f "Decimal or HEX serial number" = 0 : Decimal, 0 if omitted (omissible)
1 : HEX
[Coding Example]
Number of printing for the same contents: 1, Increment/Decrement: , Increment/decrement value: 1,
Sequential numbering digits: 5, Lower disabled digits: 0
<A>
<V>100<H>100<P>2<L>0202
<F>1+1,5,0<XM>0123456789ABCDEF01234567
<F>1+1,5,0<IP0> e:h,epc,0123456789ABCDEF01234567;
<Q>10
<Z>
[Notes]
1. Sequential number can be specified up to 1 point per format.
2. Black/white reverse image printing <(> cannot be specified for sequential number data.
3. Auto linefeed <E> is not available.
4. EPC sequential numbering is enabled only when specified immediately before the EPC code write (<IP0> command).
5. The only EPC area is targeted for the sequential numbering.
6. Note that sequential numbering is applied to converted EPC code when SSCC96/SGTIN96 code conversion is used together
with the sequential numbering.
7. This command can be used together with sequential numbering of character and barcode, up to 8 places in one item
including EPC sequential numbering.
8. This command cannot be used with the item that doesn't have print command. However, this command can be used when
blank label feed (fsw: 1) of EPC code write command <IP0> is specified.
9. This command cannot be used in items that include the <TU> command.