211
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify PCX file print.
[Format]
<GP>aaaaa,n~n
●Parameter
a[Total bytes of PCX file]
n[Data]
[Coding Example]
<A>
<V>50<H>50<GP>04500,XXXXXXXXXXXX
<Q>2
<Z>
[Notes]
1. Data is sent in binary data (Outputs 8-bit data as 1 font data all at once). (The file size of PCX file is the total bytes of PCX
file, and PCX file data are data)
2. If [Total bytes of PCX file] are not matching the transfer data, this may become the cause of malfunction.
3. Total bytes are the file size displayed at [Property] and such.
4. PCX file is available in Black/White mode only. In color mode, printing will not be performed due to command error. Also, this
command is not valid for the PCX compressed file.
Make sure that the file extension is set to [PCX] before printing.
5. Rotation <%> and Enlargement <L> are enabled.
6. It is necessary to put enlarge command <L> just before the PCX file command <GP> for enlargement.
7. Specify in the order of rotation command <%> and enlarge command <L> when specifying both commands.