285
15.12 Intelligent Command
ESC+IW Print Start Waiting Time
15.12
ESC+IW
Hexadecimal
code
ESC
IW
Parameter
<1B>
16
<49>
16
<57>
16
aaaaaa
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The parameter preset will be invalid.
Valid range between item
The parameter preset will be invalid.
[Function]
Specify the waiting time to the print start.
[Format]
<IW>aaaaaa
●Parameter
a[Print start waiting time] = Valid range : 0 999999(1 = 5ms)
[Coding Example] Wait until 5 second has been passed
<A>
<IW>1000
Print Data
<Q>1
<Z>
With the above example, the printer waits for 5 seconds after print data edition has been finished, then print the data.
[Notes]
1. When there are multiple item continuously received, the printer starts printing after the time specified by this command
has been passed from the previous item print finish.
2. This command is valid only for the first label when multiple print is specified by <Q> command, and it will be printed
continuously without waiting time from the second label.
3. This command is invalid when external signal is enabled.
4. Specify this command together with print data. This command is invalid when there are not print data.
5. When there is a printer error or the printer becomes the offline state while waiting for print start, the printer waits again
for the specified time when the printing has been resumed.
6. When the printing has been stopped by receiving print stop request command (DLE) while waiting for print start, the
waiting for print start is also stopped. When the printing has resumed by receiving print start request command (DC1),
the waiting time is resumed at the stopped time.
7. The printer will not wait for print start when reprint by reprint command <C> or function key.