8
Example of Command Reference 4
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The set parameter is valid until next specification is
made.
Valid range between items
The set parameter becomes initial value at the next
item <A>.
[Function]
Specifying the enlargement ratio of print font.
[Format]
<L>aabb
● Parameter
aa[Horizontal enlargement ratio] = Valid range: 01 to 36
bb[Vertical enlargement ratio] = Valid range: 01 to 36
[Coding Example] Horizontal enlargement ratio: 4 times, Vertical enlargement ratio: 3 times
<A>
<V>100<H>200<P>3<L>0403<XM>ABCD
<Q>2
<Z>
[Note]
The character pitch is enlarged at the same time. When the character pitch command <P> is also used, the
parameter of horizontal enlargement ratio specified by the enlargement command <L> becomes valid with
the next character pitch <P>.
[Remark]
When enlarging, design the print format so that the image will not exceed the printable area.
[Valid Commands]
1. Command classification
There are "Control", "Print position", "Modification", "Font", "Barcode", "2D code", "Graphics", "System", "Memory card",
"Enhanced function", and "Calendar."
2. Command name
3. Command code
4. Command in HEX code
5. Parameter added to the command
6. Command default
Enlargement