204
10.8 2D code
ESC+FX DataMatrix(ECC200)Sequential
10.8
Numbering(Compatible Commands)
ESC+FX
Hexadecimal
code
ESC
FX
Parameter
<1B>
16
<46>
16
<58>
16
aaabcccdddeee
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The parameter preset will be invalid.
Valid range between item
The parameter preset will be invalid.
[Function]
Specify sequential numbering of DataMatrix (ECC200).
[Format]Sequential numbering
<FX>aaabcccdddeee
●Parameter
a[Number of printing for the same contents] = Valid range : 001~999
b[Increment/Decrement flag] = + : Increment
- : Decrement
c[Number of increment/decrement] = Valid range : 001~999
d[Digit position specification] = Valid range : 001~999
e[Number of digit] = Valid range : 001~999
[Coding Example] Number of printing for the same contents: 001, Increment/Decrement flag: +,
number of increment/decrement: 001, digit position specification: 005, number of digits: 003
<A>
<V>100<H>200
<FX>001+001005003
<BX>01200202000000001
<DC>00006000
<Q>2
<Z>
[Important]
This command is for existing models. Using DataMatrix (ECC200) command <2D50> is recommended