132
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify the MaxiCode.
[Format](setting part)
<2D20>,a(,bbb,ccc,d~d)
●Parameter
a [Mode] = 2 : For carrier (numeric)
3 : For carrier (alphanumeric)
4 : Standard code
6 : For reading device
* Please specify the below parameter when mode 2 or 3 is specified.
Please omit the below parameter when mode 4 or 6 is specified.
b[Service class] = Valid range: 001~999 (numeric)
c[Country code] = Valid range: 001~999 (numeric)
d[Postal code] = Valid range: 0~999999999 (mode 2)
000000~999999 (mode 3)
* Maximum 9 digits for mode 2 (only numeric)
Fixed to 6 digits for mode 3 (upper case only for alphabet)
[Format] (data part)
<DN>mmmm,n~n
●Parameter
m[Number of data] = Valid range : 1~138
n[Print data] = data
* 00H can not be specified.
The maximum number of
print data
Fixed to 3 digits
(Numeric only)
Fixed to 3 digits
(Numeric only)
Fixed to 6 digits
(alphanumeric)
[Coding Example] Mode: For carrier (numeric), Service class: 003, country code : 081
Postal code: 123456789
<A>
<V>100<H>200<2D20>,2,003,081,123456789
<DN>0010,0123456789
<Q>2
<Z>
[Notes]
1. The size of the MaxiCode does not vary depending on the number of data.
2. The code will not be printed when a parameter other than above is specified or number of print data does not match.
3. Specify more than 12 for the print data when mode 4 or 6 is specified. The MaxiCode that print data are equal or less
than 11 cannot be read by scanners.
4. The maximum number of print data varies depending on the print data combination when other than alphanumeric code
are used for the print data.
5. The generation module has been changed for the quality improvement. The generated image may be different, however, the
reading result is the same.
MaxiCode