237
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Invoking the contents in memory card with Registration of Form Overlay <&S>.
[Format]
<&R>,aa
●Parameter
a[Registration No.] = Valid range : 1 to 99
[Coding Example]
<A>
<CC>1
<&R>,1
<Z>
[Notes]
1. Specify slot No. of Card Slot for Use <CC> prior to this command when using.
2. This command can be combined with different registration No. and printed.
3. When registration No. is not specified, this command will be ignored.
4. If specifying unregistered No., Read/Write error will occur.
5. When registering without specifying window, Vertical Print Position <V> and Horizontal Print Position <H> will be ignored and
V1 and H1 (Start position of drawing area) will be determined.
6. When specifying and registering window, movement with <V> and <H> will be enabled.
Note that when exceeding printable area, the portion outside of the printable area will not be printed.
7. This command is not effective without a memory card.
8. The error occurs when unused or the slot which the printer is allocated is specified.
[Important]
Do not turn the printer power off when accessing to the memory. When the printer power is off while memory accessing,
the data in the accessed media may be corrupted.
[Valid Commands]
Form Overlay Call