73
48.1 ESC+T1 Registration of 16×16 dots
External Character
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Registering W16 x H16 dots external character.
[Format]
<T1>abbn~n
●Parameter
a[Selection of registered data type] = H : Registered data in hexadecimal character
B : Registered data in binary code
b[Registered font code address] = H: in the range from "21" to "7F", up to 95 items can be registered
B: in the range from 21H to 7FH, up to 95 items can be registered
n[External character registered data] = Data
[Coding Example] Registration and printing by binary code of BIG5
<A>
<CC>0
<T1>B<21>16
<00FF ・・・・・・・・・・FF00>16
<Z>
<A>
<CC>0
<V>100<H>200<K1>B<90>16<21>16
<Q>2
<Z>
Registration of 16×16 dots
External Character