217
ABCD
Stop position without
the command <EP>
Stop position with the
command <EP>
ESC+EP Print End Position
Valid range and
term of
command
When the power switch is OFF
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.
[Function]
Specifying the label stop position in the sensor invalid mode.
[Format]
<EP>
[Coding Example]
<A>
<A1>14240832
<Z>
<A>
<V>100<H>200<P>2<L>0202<XS>ABCD
<Q>2
<EP>
<Z>
e.g.)
[Notes]
1. Use this command in the sensor invalid mode.
2. Use this command in combination with Label Size <A1>.
3. When the media size is specified with <A1> in the format registration command <YS> and foam overlay registration
command (&S), do not forget to specify the print end point command <EP> in the format recall command <YR> and foam
overlay recall command <&R>.
Print End Position