279
Registration(Received Data)
aa,bb(,cccc)(,d)(,eeee)(,ffffff)(,gggg…g)
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Acquire received data from the sub port.
It is possible to store acquired data up to 32 digits for 16 blocks in the internal buffer (RAM).
The stored data can be recalled by the data acquisition command <IB> and use them as the print data.
[Format]
<IR>aa,bb(,cccc)(,d)(,eeee)(,ffffff)(,gggg・・・g)
●Parameter
a[Internal buffer number] = Valid range : 1 ~ 16
b[Acquired digit] = Valid range : 1 ~ 32
c[Received data import start position] = Valid range : 0 ~ 9999 (Omissible)
d[Digit of terminate code] = Valid range : 1 ~ 4 (Omissible)
e[Terminate code] = No code range specification, 4 digits (Omissible)
f[Timeout time] = Valid range : 0 ~ 999999(1=5ms) (Omissible)
When this parameter is omitted, the printer will not be proceeded to the next
command analysis until data for specified digit are received.
g[Data item name] = Valid range : Only alphanumeric and symbols 16 digits(omissible)
[Coding Example 1] Store the received 6 byte data to the internal buffer
(Start code, terminate code, time out time and data item name are omitted)
<A>
<IR>1,6
<Z>
[Coding Example 2] Store the received 6 bytes data to the internal buffer
(Start position and terminate code are omitted)
<A>
<IR>1,6,,,,1000,ITEM_CODE
<Z>
.
.
.
Host
Data Port
(2) Received data "123456"
.
.
.
Host
(2) Received data "ABCDEF"
Internal Buffer Registration
(Received Data)