11
2.1 Control
2.1 ESC+Z End of Data Transmission
ESC+Z
Hexadecimal
code
ESC
Z
Parameter
<1B>
16
<5A>
16
Nil
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set command is not maintained.
Valid range within item
The set command becomes invalid.
Valid range between items
The set command becomes invalid.
[Function]
Specifying the end of data transmission.
[Format]
<Z>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Notes]
1. Indicates the end of the item and to be placed at the tail of the item.
2. Use Start of Data Transmission <A> and <Z> as a set of commands.
[Remark]
If not specified this command, printing will not be performed.