231
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The set parameter is in effect until a new specification is made.
The set parameter is in effect until a new specification is made.
[Function]
Specify the label stop position adjustment in each motion temporary.
[Format]
<PO>abcc
●Parameter
a [offset] = 1 : dispense mode
3 : continuous mode
b [offset direction] = + : paper feed direction
- : backfeed direction
c [offset length] = Valid range : 00 to 99 dots
[Coding Example]
<A>
<PO>3+08
<Z>
[Notes]
1. This command is not necessary to specify at the normal label printing.
2. Specify this command when there is a particular misalignment.
Offset