203
ESC+DC DataMatrix(ECC200) Data
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify the data of DataMatrix (ECC200).
[Format](data specification part)
<DC>n~n
●Parameter
n [Print data] = data
[Coding Example] Width of cell: 02, Pitch of cell: 02,
number of cell per 1 line: 000, number of cell line: 000
Print data: 1234567890
<A>
<V>100<H>200
<BX>01200202000000001
<DC>1234567890
<Q>2
<Z>
[Note]
"00H to FFH" are available in DataMatrix (ECC200). However, it is not possible to specify 05H, 10H, 11H, 18H,
and 1BH because these are printer control codes. Specify DataMatrix <2D50> when specifying control codes
in the data.
[Important]
This command is for existing models. Using DataMatrix (ECC200) command <2D50> is recommended
* The values above are the maximum number of data available as the barcode data.
DataMatrix (ECC200)
Data (Compatible Commands)