202
DataMatrix(ECC200)( Compatible Commands)
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify DataMatrix (ECC200).
[Format](setting part)
<BX>aabbccddeeefffghh
●Parameter
a[Format ID] = Valid range : 01(Fixed)
b[Error correction level(error correction)] = Valid range : 20(Fixed)
c[Width of cell] = Valid range : 01~99(dot/cell)
d[Pitch of cell] = Valid range : 01~99(dot/cell)
e[Number of cell in per 1 line] = Valid range : 010~144
000 : Auto setting
f [Number of cell lines] = Valid range : 008~144
000 : Auto setting
g[Mirror image] = Valid range : 0(Fixed)
h[Size of the guide cell] = Valid range : 01(Fixed)
[Notes]
1. It is possible to specify 01 and 02 for the width of the cell and pitch of the cell, however, the code may not be read by a scanner.
The error occurs with 00.
2. The optimal matrix size will be set automatically when 000 is specified for both numbers of cells per 1 line and number of cell
lines.
[Important]
This command is for existing models. Using DataMatrix (ECC200) command <2D50> is recommended
DataMatrix (ECC200)
(Compatible Commands)