119
71.1 Barcode
71.1 ESC+BM UPC-A Barcode (With
HRI)
ESC+BM
Hexadecimal
code
ESC
BM
Parameter
<1B>
16
<42>
16
<4D>
16
abbcccn~n
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The parameter preset will be invalid.
Valid range between item
The parameter preset will be invalid.
[Function]
Adjusting the barcode character height of the first and the last digits to the same as that of the guide bar.
[Format]
<BM>abbcccn~n
●Parameter
a[Barcode symbology] = H : UPC-A ('H' fixed)
b[Narrow bar width] = Valid range : 01 to 36 dots
c[Height of barcode] = Valid range : 001 to 999 dots
n[Print data] = Data : 11 fixed digits
[Coding Example] Barcode symbology : UPC-A Narrow bar width : 02 Height of barcode : 120
Print data : 20123948573
<A>
<H>100<V>100<BM>H0212020123948573
<Q>2
<Z>
[Notes]
1. This command supports UPC-A only. When setting [Barcode symbology] to the value other than ‘H’, command error will
occur.
2. HRI requires the following terms.
For 8 dots/mm, [02] and [03] would be a proper value of narrow bar width.
For 12 dots/mm, [03] and [04] would be a proper value of narrow bar width.
For 24 dots/mm, [06], [07] and [08] would be a proper value of narrow bar width.
Automatic HRI printing is will not be implemented when the value other than above is specified.
3. Settings for guide bar, HRI and Ratio are as follows.
Guide bar
HRI
Ratio
Available
Available
Fixed
4. The operation when invalid parameters are specified is not guaranteed.
5. The height of the character barcode is the same when printing UPC-A by using barcode command <BD>, however, the height
of the first digit and the last digit of the character code will be the same as the guide bar when printing with UPC-A barcode
command <BM>. Also, HRI can be printed from below the first digit to the last digit because the height of the barcode is
shorter when printing UPC-A by using barcode command <BD> , however, the printable area of HRI will be narrower when
printing UPC-A with UPC-A barcode command <BM> because the first digit and the last digit's height is longer.
Print result by barcode command <BD> Print result by UPC-A barcode command <BM>
UPC-A Barcode
(With HRI)
Guide bar
Guide bar
Guide bar
Guide bar
Character barcode
Character barcode
Character barcode
Character barcode
Last digit
First digit
First digit
Last digit

Table of Contents