268
Intelligent Command 15
ESC+IK Media Feed Control
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Feed or backfeed the media for the specified length.
[Format]
<IK>a(,bbbb)
●Parameter
a[Feed direction] = 0 : Forward direction
1 : Backward direction
b[Feed length] = Valid range: Refer to the table on the next page (Omissible for forward direction)
One label will be fed when this parameter is omitted.
[Coding Example 1]
<A>
<IK>0,120
<Z>
The printing starts from the current position when print data are received without returning to the original position with
<IK>1,120.
[Coding Example 2] Feed for one label
<A>
<IK>0
<Z>
Feed 120dots for forward direction
Media Feed Control