15.15 Intelligent Command
ESC+IY Exclusive Display Start-End
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
The message area (upper and lower column) that is specified by display message command <IM> is exclusively used and
messages from the printer system will not be displayed temporarily.
[Format]
<IY>a
●Parameter
a[Exclusive display start-end] = 1 : Start exclusive display
0 : End exclusive display
[Coding Example 1] Start exclusive display
<A>
<IY>1
<Z>
[Coding Example 2] End exclusive display
<A>
<IY>0
<Z>
[Notes]
1. Do not specify this command together with other SBPL commands in the same item.
2. Send this command only when the printer is online and operation stop (waiting for receive) status.
3. The data which this command is included are not received while the printer is operating. This is true for both start/end
exclusive display. The data will be received when the printer operation stopped.
4. The icon display area is not possible to use exclusively.
5. This command is invalid when the printer is offline or error state.
6. Error messages are not displayed while the display is used exclusively. Confirm with icons only.
7. The display will not be used exclusively when message display is not specified by the <IM> command.