116
69.1 ESC+BL UPC-A Barcode (Without
HRI)
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Adjusting the barcode character height of the first and the last digits to the same as that of guide bar.
[Format]
<BL>abbcccn~n
●Parameter
a[Barcode symbology] = H : UPC-A ('H' fixed)
b[Narrow bar width] = Valid range : 01 ~ 36 dots
c[Height of barcode] = Valid range : 001 ~ 999 dots
n[Print data] = Data : 11 fixed digits
[Coding Example] Barcode symbology : UPC-A Narrow bar width : 03 Height of barcode : 120
Print data : 01234567890
<A>
<H>100<V>100<BL>H0312001234567890
<Q>2
<Z>
[Notes]
1. This command supports UPC-A only. When setting [Barcode symbology] to the value other than ‘H’, command error will
occur.
2. Settings for guide bar, HRI and Ratio are as follows.
3. The operation when invalid parameters are specified is not guaranteed.
4. The height of the character barcode is the same when printing UPC-A by using barcode command <D>, however, the height
of the first digit and the last digit of the character code will be the same as the guide bar when printing with UPC-A barcode
command <BL>.
Print result by barcode command <D> Print result by UPC-A barcode command <BL>
UPC-A Barcode
(Without HRI)