[Coding Example 4]
Optional RS is specified.
<A>
<IP1>,b:1;,RS
<Z>
[Return status example 4-1]
When the RSSI value is 10 dBm
02 Start code
38 30 30 30 30 30 30 30 34 30 30 30 30 30 30 31 EPC code (16 bytes)
20 20 20 20 20 20 .........20 20 20 20 20 20 20 Unused area is space (80 bytes)
2C 52 53 3A 31 30 ,RS:10
03 End code
* The data is consecutive in the actual use, and data is expressed in hexadecimal.
[Return status example 4-2]
When RSSI acquisition is failed
02 Start code
38 30 30 30 30 30 30 30 34 30 30 30 30 30 30 31 EPC code (16 bytes)
20 20 20 20 20 20 .........20 20 20 20 20 20 20 Unused area is space (80 bytes)
2C 52 53 3A ,RS:
03 End code
* The data is consecutive in the actual use, and data is expressed in hexadecimal.
[Notes]
1. This command cannot be specified in combination with commands other than <A> and <Z>.
2. This command is not processed when receiving during printing. Processed after printing is completed.
3. It takes a few seconds to return all return status to the host after sending this command. If the port is disconnected
before all statuses are returned to the host, RFID tag information will not be correctly returned and the data other
than return status format is returned.
4. If this command results in an error, return "EPC_Tag_Err" with ASCII characters.
5. Unused area is filled with space (20H).
6. When the USER area is read by specifying ',u' (in ASCII), the printer regards the first NULL character (00H) as the
end of the character string, and returns the character string before the NULL character. When a NULL character is
not included in the character string, the printer returns character strings up to 64 characters.