291
Secure related parameter dedicated for NXP G2iM/G2iL (Omissible)
(Cannot be used for Gen2 chips other than NXP G2iM/G2iL)
rlk:
G2I,
Read protect
Specify 0 or 1 to indicate whether read protection is to be set or canceled.
1 for set and 0 for reset. Reads in all areas will be restricted if read protect is
set.
A lock password other than “00000000” shall be used together with this. Use
the same numeric string as the lock password to reset. (Dedicated for
G2iM/G2iL)
eas:
G2I,
EAS bit data
Specify 0 or 1 as EAS bit value. 1 for set and 0 for reset.
A lock password other than “00000000” shall be used together with this. Use
the same numeric string as the lock password to reset. (Dedicated for
G2iM/G2iL)
Feed control related parameters (Omissible)
fsw:
Feed without printing
Usually, for RFID write item without print data, only writing of RFID data
is performed, and the label is not fed. (Except for cases where the tag
offset is set to other than default.) When "1" is specified in this parameter,
the label is fed even if the item does not contain print data.
When "0" is specified for this parameter, the label is not fed for the item
without print data, and the operation is the same as when fsw: is not
specified.
Valid range: 0 to 1
SSCC96/SGTIN96 standard code conversion parameters
enc:
Declaration of code
standard conversion
Declare when executing conversion according to the code standard. SSCC96
and SGTIN96 can be specified. Specifying “a” will set to SSCC96 and “c” to
SGTIN96.
The converted data is written in the EPC area. Therefore, you can no longer
use the epc: parameter identifier
Valid range: a, c
flt:
Filter value
Specify the filter value with the number from 0 to 7. Refer to the filter value
standard table described later.
com:
Company prefix
Specify the company prefix with a 6 to 12-digit decimal number.
srl:
Serial reference
In case of SSCC96, specify serial reference in 5-11 digit decimals so that in
total it is 17 digits or less when put together with the numeric string specified
in “com:”. Even if the value does not reach 17 digits, leave it as is since the
upper digits are filled with a zero inside the printer.
In the case of SGTIN96, specify the serial number with a 12-digit fixed
decimal number. Specify 274877906943 or a smaller number. A parameter
error will occur if it is less than 12 digits.
itm:
Item reference
(Only for SGTIN96)
For item reference, specify 1-7 digit decimal so that in total it is 13 digits or
less when put together with numeric strings specified in “com:”.
Even if the value does not reach 13 digits, leave it as is since the upper digits
are filled with a zero inside the printer.
Coding example of standard format (3-character parameter identifier)
[Coding example 1]
When data is written in an arbitrary length in the EPC region in the IC chip manufacturer extension specifications tag
<A>
<V>50<H>50<XM>SECURE RFID EPC DATA WRITE
<IP0>e:h,epc:01234567890123456789012345678901; (in digits that are multiples of 4)
<Q>1
<Z>
[Coding example 2]
When EPC and user memory are written in a batch in the IC chip manufacturer extension specifications tag, and
permanent locking is performed
<A>
<V>50<H>50<XM>SECURE RFID EPC & USER DATA WRITE
<IP0>e:h,epc:01234567890123456789012345678901,usr:012345678…......5676789012345678901,lck:10001;
<Q>1
<Z>