294
1 character identifier parameter format coding examples
(SSCC96 code conversion / SGTIN96 code conversion / free mapping)
[Coding example 1] Country code 49 /Company code 12345 / Serial no. 789
When SSCC 96 data is written to a Gen2 corresponding tag
<A>
<V>50<H>50<XM>49123450000000789
<IP0>e:a,c:7,s:10,f:1,d:49123450000000789;
<Q>1
<Z>
[Coding example 2] Country code 49 /Company code 12345 / Item 67890 / Serial no. 789
When SGTIN96 data is written to a Gen2 corresponding tag
<A>
<V>50<H>50<XM>4912345067890000000000789
<IP0>e:c,c:7,t:6,f:1,d:4912345067890,n:000000000789;
<Q>1
<Z>
[Coding example 3]
When free mapping data is written in the EPC area of a Gen2 corresponding tag
<A>
<V>50<H>50<BD>101080*301803CB4F48B38000000001*
<IP0>e:z,d:301803CB4F48B38000000001;
<Q>1
<Z>
[Coding example 4]
When data is written in free mapping in the EPC area of a Gen2 corresponding tag, data is written in the user area, and
at the same time, a permanent lock is applied to both the EPC and USER areas
<A>
<V>50<H>50<BD>101080*0123456789ABCDEF01234567*
<IP0>e:z,d:0123456789ABCDEF01234567,u:0123456789ABCDEF0123456789ABCDEF0123456789ABCDEF,m:10001;
<Q>1
<Z>
[Coding example 5]
When data is written in free mapping in the EPC area of a Gen2 corresponding tag, and a password lock is applied to
the EPC area. When the password is set as 12345678
<A>
<V>50<H>50<BD>101080*0123456789ABCDEF01234567*
<IP0>e:z,d:0123456789ABCDEF01234567,a:12345678,m:00101;
<Q>1
<Z>
[Notes]
1. This command can be specified for the one time in one print job.
2. In case if the EPC code could not be written, an error message will be printed and will retry or discard depending on the
retry/release setting.
3. Unused parameters are omissible.
4. In case if the settings are made to ignore the sensor, the command error occurs upon receive of this command.
5. In case of a command error due to erroneous format of print job including this command, the printer will not print labels (so as
not to waste label) but there is a short beep and the printer goes OFFLINE.
The label will not be printed until the reason of command error is removed. Please check the format and values.
6. The printer suspends data writing until it goes to online when the printer received RFID writing item that does not include print
command during offline. When the printer receives an RFID writing command during other item printing, it will write to RFID
tag after other item printing has finished.
7. In case the item does not include any print command other than this command, the printer writes to the RFID tag only, and
label is not fed. There are 6 short beeps with an RFID tag error such as writing to defective tag.
Specify fsw: 1 (or g: 1) when label feed is needed same as an RFID item with print command when the item does not include
print command.
However, a label is fed even with the item not including print command when tag offset is set other than the default value.
List of operations with items that include <IP0> command (no printing)
No printing
<IP0>
item + fsw: 1
specification
No printing
<IP0>
item +
PWP enabled
Error printing
Retry operation
Error printing
Retry operation
Error printing
Retry operation