344
16) RFID setting status request
Returns the current RFID setting status.
(1) Command SOH (01H) + RB
(2) Return status format
・In normal mode (RFID disabled)
[STX] + RFID operation mode number + [ETX]
RFID operation mode number
・In RFID Setting
[STX] + RFID operation mode number + Extended status Field length + Extended status field part + [ETX]
RFID operation
mode number
Extended status
Field length
Extended status field part
(The mode number set by <RA> command will be set to the second byte.)
(3) Return status list
Detailed Return Status Configuration at the RFID Setting.
The return status at the RFID setting is extended after the RFID operation mode number.
RFID operation
mode number
Extended status
Field length
The following size of the status field indicated by 4 digits decimal
code consists of the number from “0” (30H) to “9” (39H).
(Unit: byte)
Extended status
Field part
Refer to the table of the status field part details for details.
Status field part details (Variable size)
The information field at the RFID setting. Information is delimited by comma, and type of subsequent data is
identified by the identifier.
"Number of success", "Number of failure", "Total number",
The decimal number consists of maximum 6 digits x 3 item of '0'(30H)
to '9'(39H) and delimited by comma.
"Number of success", "Number of failure", "Total number",
The decimal number consists of maximum 6 digits x 3 item of '0'(30H)
to '9'(39H) and delimited by comma.
Return the number of retry that is set
0(30H) to 9(39H) decimal number delimited by comma.
When the error occurs in the command contained in the RFID item,
return the reply whether or not to print.
0 (30H) : Don't print
1 (31H) : Print delimited by comma
Return the tag offset value.
The decimal number consists of 3 digits of '0'(30H) to '9'(39H) and
delimited by comma.
Antenna power
value
(at writing)
Return the radio output power value. The decimal number consists of
3 digits of '0'(30H) to '9'(39H) and delimited by comma.
The dBm can be acquired by dividing this value with 10.
Antenna power
value
(at reading)
Return the radio output power value. The decimal number consists of
3 digits of '0'(30H) to '9'(39H) and delimit by comma.
The dBm can be acquired by dividing this value with 10.
Return the tag type.
With this specification, only "4: Gen2" is returned.
Return the EPC code length when EPC1 is selected.
With this specification, only "0(30h): 96bit" is returned.
Return the timeout time in the module in the range of 0(30H) to
7(37H). Change the setting of timeout/number of retry in the
module.
Return the recovery method at a tag error.
0(30H) : RETRY mode
1(31H) : RELEASE mode
Slash printing at
tag error
Return the setting of slash printing at a tag error.
0(30H) : No slash printing
1(31H) : Slash printing
ETX (HEX 03H)
(Total 3 bytes~)