OmniTrax components
OmniTrax Product Guide Page 19
OC2 sensor cable
OC2 cable is supplied on a 61 cm w X 41 cm (24 in. X 16 in.) center-diameter reel. The 300 m
cable reel weighs approximately 39.5 kg (87 lb), and the 400 m reel weighs approximately 51.5 kg
(113.5 lb). Each sensor cable includes an additional 4 m (13 ft.) of detecting cable, which allows
the detection field to build up to full strength at the start point, plus 20 m (66 ft.) of non-detecting
lead-in cable for the connection to the processor. The OC2 cables are shipped with TNC
connectors and ferrite beads. Each side of the processor requires two sensor cables (one TX
cable and one RX cable).
Note Contact Senstar Customer Service BEFORE using SC1 sensor
cable.
OC2 sensor cable (dual cable system):
• 300 m or 400 m lengths with 20 m of integral
lead-in cable
• ferrite beads and TNC connectors field-
installed
• graded foil opening for uniform detection
• requires one or two trenches, or two slots
• extremely durable
• power and data over sensor cables
• recommended for long perimeters
SC2 sensor cable (dual cable system):
• 50 m, 100 m, 150 m, 200 m lengths with
20 m of integral lead-in cable
• ferrite beads and TNC connectors field-
installed
• graded foil opening for uniform detection
• requires one or two trenches, or two slots
•durable
• power and data over sensor cables
• use for shorter perimeters
SC1 sensor cable (single cable system):
• 50 m, 100 m, 150 m, 200 m lengths with
20 m of integral lead-in cable
• ferrite beads and TNC connectors field-
installed
• graded foil opening for uniform detection
• requires one trench or slot
•durable
• power and data over sensor cables
• use in sites with hard surface slots or
numerous installation limitations
Figure 4: Available cable types
OC2 - two identical
individual cables (TX/RX)
drain
braid
dielectric
core
center
conductor
foil
outer
grey jacket
cable OD
12.07 mm ± 0.23
(0.475 ± 0.009)
semi-conductive
polyethylene jacket
SC2 - two identical
individual cables
high density
polyethylene
protective jacket
center
conductor
aluminum foil
(partial covering)
cable OD
8 mm ± 0.23
(0.315 ± 0.009)
foam core
SC1 - single siamese
cable encasing two
leaky coax cables
drain braid
foam core
center conductor
aluminum foil
(partial covering)
semi-conductive
polyethylene jacket
8.64 mm ± 0.33
(0.34 in. ± 0.013)
14.41 mm ± 0.33
(0.567 in. ± 0.013)
high density polyethylene
protective jacket