Network configuration
OmniTrax Product Guide Page 229
The following figures illustrate Silver Networks using the recommended closed loop configurations.
Figure 197: OmniTrax Silver Network wiring - fiber optic & sensor cables
Figure 198: Closed loop configuration (leap frog)
TXB RXBTXA RXA
TXA
RXA
RXB
TXB
RXB
TXB
RXA
TXA
TXB
RXB
RXA
TXA
TXA RXA
TXB
RXB
TXA
RXA
TXB
RXB
TXA
RXA
TXB RXB
first OmniTrax
processor
422/FO A >
coax B
coax
second OmniTrax
processor
last OmniTrax
processor
coax A >
422/FO B
maximum distance between processors
multi-mode fiber = 2.2 km (1.4 miles)
single-mode fiber = 10 km (6.2 miles)
sensor cables (coax) 800 m (0.5 miles)
Network Interface Unit
to Network Manager
via EIA-232 OR Ethernet OR USB
maximum 60 processors
Network
Manager
security
management
system
Network Interface Unit
Processor 2
Processor 4
Processor n
Processor 1
Processor 3
Processor 5
NOTE: The security management system and
Network Manager can reside on a single PC,
or on separate PCs.

Table of Contents