System power and data communication
Page 68 OmniTrax Product Guide
The one network power supply, single block configuration can be laid out as a closed perimeter, an
open perimeter, or in a linear configuration.
A multi-block configuration is used whenever there is a requirement to supply network power to
more than five processors via the sensor cables. One 48 VDC network power supply is used to
power each block of processors. The data connection between the blocks can be made between
any two processors, which maintain the loop configuration. For multi-block configurations, Senstar
recommends sensor cable connected blocks be limited to 5 processors per block. Overlapped
terminators ensure a closed perimeter, and a fiber optic data link provides optical isolation.
Figure 33: Open perimeter, single block configuration
Figure 34: Linear configuration
Figure 35: Closed perimeter, multi-block configuration
1 2
3
5 4
48 VDC
power
supply
standalone decoupler
network decoupler
terminator
1 2 3 4
5
48 VDC network
power supply
standalone decoupler
network decoupler
terminator
fiber optic data link
48 VDC network
power supply
standalone decoupler
network decoupler
terminator
48 VDC network
power supply