50. Identity (0x1,018).....................................................................................................180
51. Sync Manager Communication Type (0x1C00)...................................................... 180
52. Sync Manager 2 PDO Assignment (process data output, 0x1C12)......................181
53. Sync Manager 3 PDO Assignment (process data input, 0x1C13)........................ 181
54. Safety Configuration Check (0x2,000)................................................................... 181
55. Current Error (0x2,100)........................................................................................... 181
56. Operation time (0x2110)......................................................................................... 182
57. Config info (0x2,120)...............................................................................................183
58. Device Info (0x2,130).............................................................................................. 184
59. FSoE Connection Communication Parameter (0x9,001)...................................... 185
60. FSoE Connection Diagnosis (0xA000).................................................................... 185
61. Modular Device Profile (0xF000)............................................................................ 186
62. Detected Module List (0xF050)...............................................................................186
63. Device FSoE Slave Address (0xF980).....................................................................186
64. microScan3 Core – EtherCAT® ordering information............................................ 188
65. microScan3 Pro – EtherCAT® ordering information.............................................. 188
66. Safety laser scanner without system plug..............................................................189
67. System plug.............................................................................................................. 189
68. Additional spare parts..............................................................................................189
69. Reference target.......................................................................................................190
70. Testing equipment....................................................................................................190
71. Note on standards....................................................................................................195
LIST OF TABLES 20
8025220/1L9Q/2023-08-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCA
205
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK EtherCAT microScan3 and is the answer not in the manual?

SICK EtherCAT microScan3 Specifications

General IconGeneral
Scanning angle275°
InterfacesEtherCAT
Protection classIP65
Supply voltage24 V DC
Resolution for protective field30 mm
Operating voltage24 V DC
Scanning range5.5 m
Number of fields128
Number of monitoring cases128
Response time30 ms
Operating temperature0 °C to 50 °C
Field of applicationIndustrial safety
Light sourceInfrared laser, 905 nm
Connection typeM12
Weight1.2 kg