4-1
The Quick CFIG option provides you with the ability to quickly and
automatically program the components and features of the 4010. Quick CFIG is
especially useful for programming basic system components following a new
installation, and for adding components to an existing installation.
Quick CFIG functions include the following:
• Reconfigure All Hardware
• Autodetect all new hardware added since CFIG was last saved
• Restore the Factory CFIG
• Accept default settings for system options
• Edit settings of system options
Be alert to the following when using Quick CFIG:
• WARNING: The 4010 System will NOT continue to operate as a Fire
Alarm System during the programming of Quick CFIG operations.
• Quick CFIG performs an IDNet duplicate address search, and terminates if
duplicate addresses are found.
• Using the Quick CFIG options changes the 4010 configuration. When
changing the configuration, information could be lost.
• Quick CFIG is not allowed if a DACT or Network card is installed. Use
Quick CFIG first, and then program the DACT or network card.
• Class A Adapters are not automatically detected by Quick CFIG. Refer to
Chapter 6 for information on programming a Class A NAC.
• TrueAlert Non-Addressable functions are not accessible through Quick
CFIG. You must manually program the appropriate NACs with the
TrueAlert point type to enable TrueAlert operation. Refer to Chapter 6 for
information on manually programming a NAC’s point type.
• Quick CFIG automatically configures the hardware device type for a 4009
(4009A, R4009A, 4009A8, R4009A8). All 4009 NACs are set for Class B
operation and assigned a point type of SSIGNAL.
This chapter discusses the following topics:
Topic See Page #
Reconfigure All Hardware 4-2
Auto Detect New Hardware 4-3
Restore Factory CFIG 4-4
Accept Default Settings for System Options 4-5
Edit Settings for System Options 4-6
Chapter 4
Quick CFIG
Overview
Cautions and Warnings
In this Chapter
Pro
g
rammin
g
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Other manuals for Simplex 4010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4010 and is the answer not in the manual?

Simplex 4010 Specifications

General IconGeneral
BrandSimplex
Model4010
CategoryFire Alarms
LanguageEnglish

Related product manuals