Operation 4
Display messages
Code
Shown on display Description/possible solution
A3230
Fault: Monitoring of
steering
Collective fault on the steering
A3340
Monitoring: Electrics
Collective fault on the additional electrical
installation
A3345
Monitoring: Electrics
Collective fault on the powertrain
A3346
Monitoring: Drive unit
Collective fault on the drivetrain
A3347
Hydraulics
If no attachment is fitted, this message can be
ignored.
- If there is an attachment fitted, contact the
authorised service centre.
A5090
Overtemp.: Drive unit
Drive unit overtemperature collective fault
- Switch off the truck and leave it to cool down.
A5091
Overtemp.: Hydraulic
drive
Hydraulic drive overtemperature collective fault
- Switch off the truck and leave it to cool down.
A5934
Fault: Internal
charger
Error on the charging connector detection
- Disconnect the connection assembly and
reconnect it.
A5961
Battery overtemperature
Overtemperature of the lithium battery
- Switch off the truck and leave it to cool down.
A5962
Battery too cold
Insufficient lithium battery temperature
- Move the truck to a warmer environment.
A5986
Fault: Control unit
General battery current measurement
A5993
Fault: Internal
charger
On-board charger collective fault
A6210
Fault: Battery
Lithium battery collective fault
A6502
Overtemp.: Parking
brake
Electric parking brake detects overtemperature
A6510
Fault: Parking brake
Electric parking brake detects fatal fault
A6511
Fault: Parking brake
Brake cannot release
A6512
Fault: Parking brake
Brake cannot apply
A6701
Fault: Monitoring of
assistance system
Collective fault on the assistance systems
None
Error
General fault
.
563
68011531 EN - 06/2019 - 02 295