User’s Manual
146 Software Configuration
Import Patch from LIGHTWRIGHT®
Patch information can also be imported from a LIGHTWRIGHT® file. You will first need to export from
LIGHTWRIGHT® as a CSV file and keep all default column settings and assignments.
Print Patch
Select "Print Patch" to print all patched channels to a system printer.
Use the print preview and printer settings to adjust the look and layout of the patch information that will be sent to the
printer.
Print Settings
This allows the user to set the print settings of the document.
Release All Captured Dimmers
If a dimmer has been manually set to a value it is considered captured. This means that regardless of the desk channel
setting the output of that dimmer will remain at its captured value. Captured dimmers are identified by a red number
showing in the top right hand corner of the channel.
To release all channels back to regular control select this option from the menu. This can also be achieved by entering
"dim rel" in the command line interface.
Highlight Dimmers Used by Channel Selection
Will highlight the output assigned to the selected channel/fixture.
Show Patched Addresses as Absolutes
By default, patched address will display as "Universe.Address". So the first address in the second universe will be
"2.1". If this option is checked, the address will show as the absolute DMX values of 513.
Replace Other Channels When Drag and Drop Patching
When using the GUI solution of drag and drop patching, the new channel will replace the old channel assignment
with this in the default position of on. If turned off, drag and drop patching shall add to the current assignment.
Patching Fixtures in Reverse Order
When doing range patching, will patch the list of items in reverse order rather than in numerical order.
Automatically Look Up Text When Typing
When you are in a cell of the grid and you start typing test it will try to auto complete based on what's already in the
grid. Similar to the way Excel does.
First Dip Switch Value is 0
The last column in the grid shows the dip switch settings. You can use this setting to change if the dip switches start at
0 or 1.
Show / Hide Search Bar
This will reveal or hide the patch search bar.
Create Palette Automatically When Patching Fixtures
When an automated luminaire is patched, this gives you the option of having the NEO software automatically create
palettes based upon the patched fixtures wheel assignments. This will create palettes for colors and gobos.
Reset Grid Layout to Default
This resets all column width settings to default.
Save Patch
A patch change is not automatically saved. This is to allow you to make changes to the patch and revert back should
those changed not be desired.
This will save the patch changes to the show file.
Save Patch and Close Window
This will save the patch changes and close the patch window taking you back to the Live screen.