Objet30 User Guide 6 Operating and Maintaining the Printer
DOC-34025 Rev. I 6-109
Use the following checklist to perform the preventive maintenance routine.
Wiper Assembly
o Clean the area surrounding the wiper.
o Replace the wiper.
See "Cleaning and Replacing the Wiper" on page 6-37.
Materials Drawer
o Calibrate all the load cells.
See "Calibrating the Load Cells" on page 6-75.
o Replace the waste container.
See "Replacing the Waste Container" on page 6-104.
o Replace the Model and Support material filters.
See "Replacing the Material Filter" on page 6-84.
o Replace the Model, Support and Waste material pump-tubes.
See "Replacing the Pump Tubes" on page 6-92.
Roller Waste Collector
o Replace the roller waste collector.
See "Cleaning and Replacing the Roller Waste Collector " on page 6-
43.
UV Lamp
o Replace the black strip in the UV reflector.
See "Replacing the UV Lamp" on page 6-79.
o Clean the glass lens of the UV lamp assembly with the special 3M
cleaning pad.
o Clean the glass covering the UV sensor (to the right of the build tray).
o Calibrate the UV lamp intensity
See "Testing and Calibrating the UV Lamp" on page 6-71.
Print Heads
o Clean the print heads with the Head Cleaning Wizard
See "Cleaning the Print Heads and the Roller" on page 6-34.
o Perform the Pattern Test
See "Pattern Test" on page 6-40.
o Check the alignment of the print heads
See "Aligning the Print Heads" on page 6-47.
o Run the Head Optimization Wizard
See "Optimizing (Calibrating) Print Heads" on page 6-51.