February, 2008
2-646
WorkCentre 5225, 5230
123-332, 123-333
Launch Version
Status Indicator Raps
123-332 Interface Parameter RAP
The UI software failed and an incorrect parameter was received by the DM-CP driver interface.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 11.2) and P/J388 on
the ESS PWB (PL 9.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 11.2).
If the problem persists replace the ESS PWB (PL 9.2).
123-333 Interface Communication RAP
The system detected that transmission with the Control Panel could not be established.
The H/W connection in the UI is faulty and the internal connection isn’t detected.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 11.2) and P/J388 on
the ESS PWB (PL 9.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 11.2).
If the problem persists replace the ESS PWB (PL 9.2).