5.1 Manipulating Parameters (Pn)
5.1.4 Write Prohibition Setting for Parameters
5-8
Restrictions
If you prohibit writing parameter settings, you will no longer be able to execute some functions.
Refer to the following table.
SigmaWin+ Digital Operator
When Writing
Is Prohibited
Reference
Button in
Menu
Dialog
Box
SigmaWin+ Function
Name
Fn No. Utility Function Name
Setup
Origin Search
Fn003 Origin Search
Cannot be
executed.
page 7-20
Absolute Encoder Reset Fn008 Reset Absolute Encoder
Cannot be
executed.
page 5-48
Adjusting the Analog
Monitor Output
Fn00C
Adjust Analog Monitor Output
Offset
Cannot be
executed.
page 9-10
Fn00D
Adjust Analog Monitor Output
Gain
Cannot be
executed.
page 9-10
Motor Current Detection
Offset Adjustment
Fn00E
Autotune Motor Current
Detection Signal Offset
Cannot be
executed.
page 6-36
Fn00F
Manually Adjust Motor
Current Detection Signal
Offset
Cannot be
executed.
Multiturn Limit Setting
Fn013
Multiturn Limit Setting after
Multiturn Limit Disagreement
Alarm
Cannot be
executed.
page 6-26
Reset Configuration Error
of Option Module
Fn014
Reset Option Module
Configuration Error
Cannot be
executed.
page 15-50
Vibration Detection Level
Initialization
Fn01B
Initialize Vibration Detection
Level
Cannot be
executed.
page 6-32
Setting the Origin of the
Absolute Linear Encoder
Fn020
Set Absolute Linear Encoder
Origin
Cannot be
executed.
page 5-50
Software Reset Fn030 Software Reset
Can be exe-
cuted.
page 6-30
Polarity Detection Fn080 Polarity Detection
Cannot be
executed.
page 5-26
Set Origin Fn200 Tuning-less Level Setting
Cannot be
executed.
page 8-15
EasyFFT Fn206 Easy FFT
Cannot be
executed.
page 8-89
− FnB09 Set Absolute Encoder Origin
Cannot be
executed.
page 12-6
Parame-
ters
Initialize*
FnB0B
Initialize INDEXER Parameter
Settings
Cannot be
executed.
page 5-10
Tuning
Autotuning without
Reference Input
Fn201
Advanced Autotuning
without Reference
Cannot be
executed.
page 8-23
Autotuning with Reference
Input
Fn202
Advanced Autotuning with
Reference
Cannot be
executed.
page 8-34
Custom Tuning Fn203 One-Parameter Tuning
Cannot be
executed.
page 8-41
Anti-Resonance Control
Adjustment
Fn204
Adjust Anti-resonance
Control
Cannot be
executed.
page 8-49
Vibration Suppression Fn205 Vibration Suppression
Cannot be
executed.
page 8-54
Continued on next page.