16.2 List of Parameters
16.2.2 List of Parameters
16-9
Pn00A
2
Application Function
Selections A
0000h to
1044h
–
0001h All
After
restart
Setup
–
Pn00B
2
Application Function
Selections B
0000h to
1121h
–
0000h All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Motor Stopping Method for Group 2 Alarms Reference
0
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 = n.X).
page 5-36
1
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.
2
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
4
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then let the motor coast.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
Operator Parameter Display Selection Reference
0 Display only setup parameters.
page 5-3
1 Display all parameters.
n.X
Motor Stopping Method for Group 2 Alarms Reference
0 Stop the motor by setting the speed reference to 0.
page 5-361
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 = n.X).
2 Set the stopping method with Pn00A = n.X.
n.X
Power Input Selection for Three-phase SERVOPACK Reference
0 Use a three-phase power supply input.
page 5-13
1
Use a three-phase power supply input and as a single-phase
power supply input.
n.X Reserved parameter (Do not change.)