17.1 Corresponding SERVOPACK and SigmaWin+ Function Names
17.1.2 Corresponding SERVOPACK Monitor Display Function Names
17-7
17
Appendices
*1. You can use Un010 to monitor the upper limit setting for the maximum motor speed or the upper limit setting for
the encoder output resolution.
You can monitor the upper limit of the encoder output resolution setting (Pn281) for the current maximum motor
speed setting (Pn385), or you can monitor the upper limit of the maximum motor speed setting for the current
encoder output resolution setting.
Select which signal to monitor with Pn080 = n.X (Calculation Method for Maximum Speed or Divided Out-
put Pulses).
If Pn080 = n.0, the encoder output resolution (Pn281) that can be set is displayed.
If Pn080 = n.1, the maximum motor speed (Pn385) that can be set is displayed in mm/s.
*2. This applies to the following motors. The display will show 0 for all other models.
SGM7J, SGM7A, SGM7P, SGM7G, SGM7E, SGM7F, and SGMCV
Service
Life Moni-
tor
Installation Environment Monitor
SERVOPACK
Un025
SERVOPACK Installa-
tion Environment Moni-
tor [%]
Installation Environment Monitor
Servomotor
*2
Un026
*2
Servomotor Installation
Environment Monitor
[%]
Service Life Prediction Monitor
Built-in Fan
Un027
Built-in Fan Remaining
Life Ratio [%]
Service Life Prediction Monitor
Capacitor
Un028
Capacitor Remaining
Life Ratio [%]
Service Life Prediction Monitor
Surge Prevention Circuit
Un029
Surge Prevention Circuit
Remaining Life Ratio
[%]
Service Life Prediction Monitor
Dynamic Brake Circuit
Un02A
Dynamic Brake Circuit
Remaining Life Ratio
[%]
Product
Informa-
tion
Motor Resolution
Un084
Linear Encoder Pitch
(Scale pitch = Un084 ×
10
Un085
[pm])
Un085
Linear Encoder Pitch
Exponent (Scale pitch =
Un084 × 10
Un085
[pm])
Un020
Rated Motor Speed
[min
-1
]
Un021
Maximum Motor Speed
[min
-1
]
Continued from previous page.
SigmaWin+ SERVOPACK
Button in
Menu
Dialog Box
Name [Unit] Un No. Name [Unit] Serial Command

Table of Contents