Call routing
238
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
6. 6. 9 Call logging and Data Protection
In connection with the LCR function, the OCL output format PC5 (recommended)
or PC4 must be used (see "Output formats", page 312).
When the data protection function is activated, the following data will not be out-
put or output only in part, in OCL output format PC5 and PC4:
• The last four digits of the phone number dialled by the user will be truncated.
• The last four digits of the phone number dialled by the LCR function will be trun-
cated.
• User IDs and PIN codes will not be output.
• User IDs and PIN codes will also be suppressed when the LCR tables are printed
out.
6. 6. 10 Examples of LCR
Fig. 101 1. Example: Network provider B is integrated in the numbering plan of network provider A
Tab. 73 1. Example: Entry in the network provider table
Network Pro-
vider
Access
code
Route Barring Conversion rule User ID PIN
Charge code
length
Network
provider B
132 – – EN – – –

Table of Contents

Other manuals for Aastra 400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aastra 400 Series and is the answer not in the manual?

Aastra 400 Series Specifications

General IconGeneral
BrandAastra
Model400 Series
CategoryServer
LanguageEnglish

Related product manuals