Call logging (CL)
340
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
8. 7. 7 Output formats PC1 to PC4
Output formats PC1 to PC4 are older formats which, although they are still sup-
ported, are no longer being expanded. Output format PC 5 is therefore recom-
mended for new applications.
At the end of each call the call data logged is printed out on one of the system’s
Ethernet interfaces in the CL output output type.
Data record field structure
The fields are separated by one or more "space" ASCII characters. The data import
mask must therefore take account of the position of the beginning of the field
("Offset" column in the structural descriptions below).
The symbols and conventions listed in Tab. 130 are used to format the fields:
Tab. 130 Format conventions
Certain fields take on different formats depending on the system configuration.
These exceptions are appended as notes directly after the structural descriptions.
Format field in the structural descriptions below:
Certain fields take on different formats depending on the system configuration.
I– SP: means left justified and padded with spaces.
Symbol Meaning
– I Right justified
I – Left justified
00 00 Padded with "0" up to the defined data field length
SP Padded with spaces