Call routing
273
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
Tab. 91 Settings for break-out routing at the source PINX
(PINX 1 in Geneva)
Parameter Parameter value
User configuration:
Automatic CLIP No (permanently CLIP number entry is used)
NPI E.164
TON National
CLIP number 022 827 9x xx
(x stands for the users DD number)
LCR table:
... ...
01 810 Zurich (allocate to the "Zurich" routing table)
01 811 Zurich (allocate to the "Zurich" routing table)
01 813 Zurich (allocate to the "Zurich" routing table)
... ...
"Zurich" routing table:
Time zone x•Network provider: BreakOutZH
Time: Allocate the times for "BreakOutZH"
Network operator table:
Network provider "BreakOutZH" Route 5
Conversion rule N (add dialled phone number)
Route 5:
Name Zurich, ISDN exchange
Trunk groups 2
Digit barring No (do not consult digit barring)
Outgoing connections Number of connections allowed simultaneously
Numbering plan identifier NPI E.164
Type of number TON Unknown
Trunk group 2:
Name Zurich, PINX 2
Network interfaces Network interfaces of this trunk group
Network type Private
Protocol QSIG or QSIG / PSS1 ISO
Automatic CLIP yes