Features
541
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
Switch Group Assignment
Each function can be assigned one of the switch groups 1 - 20. This allows you, for
example during holiday periods, to activate or deactivate whole groups of func-
tions. All functions with allocation of the corresponding switch group are active on
switch postion 1 and inactive on switch positions 2 + 3.
Tab. 364 Activating/deactivating functions via switch groups:
Note:
When switch groups are switched over, the functions are maintained in
their status at the time.
Available Functions
All remote-controlled functions can be activated with time control. User-specific
features are activated with *06 <user No.>. For an overview of the functions availa-
ble see Tab. 356 and Tab. 357. In addition to the remote-controlled features the fol-
lowing functions can also be activated using time control:
Tab. 365 Additional time-controlled functions
No
.
Func-
tion
codes
Start
(Day)
Stop
(Day)
Execution
date
Execu-
tion time
Switch
group
Meaning
5 *931 02 Monday Friday 07:00 7 Activate welcome announcement
02 of the announcement service
6 #931 02 Monday Friday 18:00 7 Deactivate welcome announce-
ment 02 of the announcement serv-
ice
7 *85072 20.12.2002 18:30 Switching from switch group 7 to
switch position 2: All functions allo-
cated switch group 7 are deacti-
vated.
8 *85071 06.01.2003 06:30 Switching from switch group 7 to
switch position 1: All functions allo-
cated switch group 7 are activated.
Feature Activate Reset
Activate / deactivate welcome announcement of the
announcement service
*931 <No of the wel-
come announcement>
#931 <No of the wel-
come announce-
ment>
Enable/bar a one-off remote access *754 #754
Enable/bar a permanent remote access *753 #753