EasyManua.ls Logo

ABB IRB6400 - Page 273

ABB IRB6400
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical
Troubleshooting Guide
IRB6400 M94A
Page 10 - 26
Calibration Procedures
Counter Updating Procedure (Cont)
4. Move the cursor to the desired axis to be updated
and press INCL or press ALL to include all axis.
The selected axis will be marked with an “X”.
5. Press OK. A warning message will be displayed. If
everything is correct then press OK again.
6. It is very important after completing this procedure
to load and run the calibration program on the Boot
Disk 4. Explanations on how to do this is in the
software loading chapter. If the calibration marks
do not line up after running the calibration program
repeat procedure for axis that are off. If
mispositioning persists the resolver system must
be repaired. If a problem occurs for Axis 6 the
cause may be that Axis 6 has been rotated to the
wrong revolution. If the correct revolution can not
be found then the axis must be recalibrated using
one of the previous procedures.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for ABB IRB6400

Related product manuals