Error Messages
40041: Name error ................................User's Guide
Label name ambiguous.
Labels must have names that are unique within the routine. Rename the label or change
the conflicting name.
40042: Name error ................................User's Guide
Module name ambiguous.
Modules must have names that are unique among all the global data, global routines and
modules in the entire task program. Rename the module or change the conflicting name.
40043: Name error ................................User's Guide
Parameter name ambiguous.
Parameters must have names that are unique within the routine. Rename the parameter
or change the conflicting name.
40044: Name error ................................User's Guide
Persistent name ambiguous.
Program data must have names that are unique within the module. Rename the data or
change the conflicting name.
40045: Name error ................................User's Guide
Routine name ambiguous.
Routines must have names that are unique within the module. Rename the routine or
change the conflicting name.
40046: Name error ................................User's Guide
Persistent name already in sdb.
No two persistent data in the same task program, including predefined Persistents, may
share the same name. Rename one of the Persistents.
40047: Name error ................................User's Guide
Variable name ambiguous.
Routine data must have names that are unique within the routine. Program data must
have names that are unique within the module. Rename the data or change the conflicting
name.
40048: Type error ................................User's Guide
Operand types for binary + or - operator not equal.
The two operands of the + and - operators must have equal type.
Check the operand types.
Programming Error Messages (Cont)