Appendix A - 71
Error Messages
Electrical
Troubleshooting Guide
IRB6400 M94A
71017: No activate signal..........................Chapter 11
DescriptionReason: Missing activate signal for cross. Check:
1. One activate signal must be given
71018: Activate signal overflow....................Chapter 11
DescriptionReason: Number of activate signals for cross to high. Check:
1. Only one activate signal must be given
71019: Missing signal definition................... Chapter 11
DescriptionReason: The signal: %s, at cross is not defined. Check:
1. Define the signal name in signal section
71020: No result signal............................Chapter 11
DescriptionReason: Missing result signal. Check:
1. At least one result signal must be given
71021: Duplicate cross signals.....................Chapter 11
DescriptionReason: The signal: %s, appears both as FROM and as TO. Check:
1. The same signal can not be given for both FROM and TO
71022: Physical max too high.......................Chapter 11
DescriptionReason: Signal: %s. Check:
1. Change value in configuration
71023: Physical min too low........................Chapter 11
DescriptionReason: Signal: %s. The physical min value < %d. Check:
1. Change value in configuration
71024: Physical value too high.....................Chapter 11
DescriptionReason: Signal: %s. Value set to Maxvalue. Check:
1. Change physical max value in configuration
71025: Physical value too low......................Chapter 11
DescriptionReason: Signal: %s. Current value = %d < Minvalue = %d. Value set to
Minvalue. Check:
1. Change physical min value in configuration