Appendix A - 73
Error Messages
Electrical
Troubleshooting Guide
IRB6400 M94A
71034: Digital output out of range................. Chapter 11
DescriptionReason: The number of digital outputs is out of range at board address %d
max outputs are %d. Check:
1. Change the configuration for the board
71035: Starting quarter out of range............... Chapter 11
DescriptionReason: The starting quarter is out of range for board %s. Check:
1. The starting quarter must be within the values 0 to 3
2. Change the config file
71036: Name out of range...........................Chapter 11
DescriptionReason: The number of characters in name %s is greater than %d characters.
Check:
1. Give a new name that fits within the limits
71037: IO Cross connection fault................... Chapter 11
DescriptionReason: The signal %s appears on both FROM and TO in the same chain.
Check:
1. Correct the configuration for the crossconnections there the signal above is connected
71038: IO Cross depth to high......................Chapter 11
DescriptionReason: The Cross connection in the same chain is too deep. First signal
name: %s. Check:
1. Make the Cross connection less deep
71039: Max instances out of range.................. Chapter 11
DescriptionReason: The max number of instances for driver %s is out of range. Check:
1. Make sure that the number of instances is greater than 0, and not more than number
of IO slots
71040: RIO link address out of range............... Chapter 11
DescriptionReason: The RIO link address for board %s is out of range. Check:
1. Make sure that the RIO link address is greater than 0, and less than 64
71041: Analog output overflow......................Chapter 11
DescriptionReason: Number of analog output for board, %s is greater than %d. Check:
1. Reduce the number of analog outputs
71042: Analog inputs overflow......................Chapter 11
DescriptionReason: Number of analog inputs for board, %s is greater than %d. Check:
1. Reduce the number of analog inputs