Electrical
Troubleshooting Guide
IRB6400 M94A
Appendix A - 74
Error Messages
71043: Signal type error...........................Chapter 11
DescriptionReason: The type specified for signal %s cant be connected to specified
board. Check:
1. Change to another type
2. Change to another board
71044: Physical signal overflow....................Chapter 11
DescriptionReason: The range of phsig, or length, or phsig and length for signal %s is
greater than %d. Check:
1. Change the physical signal number
2. Change the length
71045: Filter specification error.................. Chapter 11
DescriptionReason: Signal %s: No filter time can be specified for this type of signal.
Check:
1. Set filter time to 0 or remove the statement
71046: Scaling error...............................Chapter 11
DescriptionReason: Signal %s: No scaling can be done. Check:
1. Remove the scaling statements
71049: Parameter Invert error......................Chapter 11
DescriptionReason: Signal %s: This type of signal cant be inverted. Check:
1. Only digital signals can be inverted
71050: Signal for cross not digital................ Chapter 11
DescriptionReason: Signal %s: Is not a digital signal. Check:
1. Only digital signals can be cross connected
71051: Link address not octal......................Chapter 11
DescriptionReason: Signal %s: The RIO address is not in octal form. Check:
1. Reenter a new address in octal form
71052: Cross table full............................Chapter 11
DescriptionReason: The cross connection can only contain %d signals. Check:
1. Reduce the number of signals
71053: RIO connection down.........................Chapter 11
DescriptionReason: CantaccessRIOboarddueto’ communication with PLC is down. Check:
1. Check the communication cable to PLC
2. Check of if the PLC is switched off