File
1
OVERVIEWCALL SERVER : HOTEL
Ed. 04 3/6Réf. 3EH 21000 BSAA
HOTEL INSTALLATION
When the system is brought into service, the PM5 Easy View session allows you to specify that the ins-
tallation is a hotel installation. By doing this, the system automatically creates predefined profiles (Re-
ception set, phone booth, room sets, administration sets, etc) described below:
- the first set is the Operator Station; this 4034/Advanced set in PABX mode belongs to all active
operator groups as well as the default operator group.
This set has the profile of a Reception set: it has a direct call key for the booth station and, on the
add-on-modules, a direct call key for each room set in the installation (up to 80 sets).
- the Reflexes sets are administration sets.
- the Z sets (except fax machines and booths) are room sets.
- dynamic routing level 1 for administration sets: any unanswered call is routed to the voice mail unit
after 12 seconds.
- dynamic routing level 2 for administration sets: any unanswered external call is routed to the ope-
rator group after 24 seconds; for room sets, this mechanism only applies after customer check-in.
- OS calls overflow to general level (default operator group) after 24 seconds; for room sets, this
mechanism only applies after customer check-in.
- the first Z interface is configured to connect a fax machine (VOICE and FAX2/3 services; no dyna-
mic routing; protection against camp-on, intrusion and camp-on tone).
- the second Z interface is configured to connect a booth station (automatic call setup on going off-
hook, delayed by 3 seconds, meter total recall at the operator station).
- the internal numbering plan is programmed with the prefixes for "room status," "room service" and
"wake-up programming".
- the public numbering plan (if the public numbering system is "open") contains 2 ranges of DDI
numbers: one for the OS, the other for the administration sets, the booth and the Z interface of the
fax machine; the DDI numbers correspond to the internal call numbers of the sets.
The remaining ranges can be used for the room sets.
- the table of features in conversation is programmed with the default codes for the features "DND
override", "trunk allot" and "meter total recall".
- all the programmable keys on Easy, Premium and Advanced sets are modifiable by the user (or by
the installer).
Using the pre-defined profiles of the PM5 Easy View session means you can avoid some of the system
programming described in the "Configuration" section.
See the "Starting Up" section of the installation manual for a description of the PM5 Easy View session;
this session also enables you to configure some of the key Hotel application parameters (the DDI num-
bers, for example) right from the initialization stage.